Description
Complete 8-in-1 Digital Water Quality Tester
A comprehensive look at your water, with eight measurements in one device.
Water has many measurable characteristics, from its dissolved mineral content and acidity to conductivity, salinity and temperature. Understanding these characteristics can help you observe changes between water sources and monitor the conditions within a variety of water systems.
The Complete 8-in-1 Digital Water Quality Tester brings together eight measurement functions in one compact handheld instrument, allowing you to explore multiple water parameters without using separate testing devices.
With the addition of chlorine-related measurement alongside pH, TDS, EC, salinity, ORP, specific gravity and temperature, it offers the broadest range of functions in our water tester collection.
Whether you’re comparing tap and filtered water, monitoring an aquarium or assessing selected characteristics of treated water, this versatile tester provides useful information for more informed water monitoring.
Understanding the Eight Measurements
1. pH – Acidity & Alkalinity
pH describes how acidic or alkaline water is, generally expressed on a scale from 0 to 14.
Below pH 7: Acidic
pH 7: Neutral
Above pH 7: Alkaline
Monitoring pH can help you understand changes in acidity or alkalinity, including those associated with filtration, remineralisation and different water sources.
pH is also important in aquariums, hydroponic growing systems and treated water applications.
2. TDS – Total Dissolved Solids
TDS represents the estimated concentration of dissolved substances in water, including mineral salts and other dissolved ions.
Readings are expressed in parts per million (ppm) or parts per thousand (ppt), depending on the concentration.
Understanding your reading:
Lower TDS: Generally indicates fewer dissolved solids.
Higher TDS: Generally indicates a greater concentration of dissolved solids.
TDS monitoring can be useful for comparing tap water and reverse osmosis filtered water or observing changes over time.
A low TDS reading does not necessarily indicate that water is free from harmful contaminants, while a higher reading may reflect naturally occurring or intentionally added minerals.
3. EC – Electrical Conductivity
Electrical Conductivity measures how readily water conducts electricity, which is influenced by the concentration of dissolved ions.
EC is displayed in microsiemens per centimetre (µS/cm) or millisiemens per centimetre (mS/cm).
Most handheld water testers estimate TDS from electrical conductivity using a conversion factor, so these two measurements are closely related.
EC is particularly useful in water filtration monitoring, hydroponics and aquariums.
4. Salinity – Salt Concentration
Salinity estimates the concentration of dissolved salts in water.
This measurement is especially useful for marine aquariums, aquaculture and other environments where monitoring salt concentration is important.
In conductivity-based testers, salinity is generally calculated from conductivity using an appropriate conversion method.
5. ORP – Oxidation-Reduction Potential
ORP measures the tendency of water to support oxidation or reduction reactions, expressed in millivolts (mV).
It provides information about electrochemical conditions and can be useful when observing changes in certain water treatment systems, aquariums and pools.
However, an ORP reading does not independently establish that water is adequately disinfected or provide evidence of antioxidant health benefits.
6. Specific Gravity (S.G.)
Specific gravity compares the density of a liquid with a reference density.
In water testing, this measurement is particularly useful for marine aquarium conditions, where dissolved salts influence water density.
Monitoring specific gravity alongside salinity and temperature can help track changes in saltwater environments.
7. Chlorine (CL)
Chlorine is commonly used to disinfect drinking water, swimming pools and spas.
The MF-X81 includes a chlorine-related measurement function, with a published range of 0–4 ppm.
This may be useful for observing changes in the tester’s chlorine-related readings when comparing treated water samples.
An important distinction: Available documentation does not establish whether the CL reading measures free chlorine, total chlorine or a calculated estimate. It should therefore not replace a validated chlorine testing method for drinking water safety, swimming pool management or spa sanitiser control.
8. Water Temperature
Temperature influences water chemistry, electrical conductivity and the conditions required for many water environments.
The Complete 8-in-1 measures water temperature in degrees Celsius or Fahrenheit, allowing you to monitor this parameter alongside the other readings.
Understanding Water Before & After Filtration
Reverse osmosis filtration is designed to substantially reduce many dissolved substances in water.
The Complete 8-in-1 can help you compare TDS, EC and pH readings from different water sources, including incoming tap water and reverse osmosis filtered water.
For meaningful comparisons, collect samples in clean containers and test under similar conditions.
What about remineralised reverse osmosis water?
Some reverse osmosis systems include a remineralisation stage that adds minerals back into the water after filtration.
Depending on the minerals added and the water chemistry, this may increase the finished water’s TDS and conductivity readings and influence pH.
An increase in TDS following remineralisation does not necessarily indicate a problem with the reverse osmosis membrane. Where an appropriate sampling point is available, testing directly after the RO membrane provides a clearer assessment of dissolved solids reduction before remineralisation.
The tester’s chlorine-related reading should not be used by itself to establish chlorine removal performance. A validated chlorine-specific test is more appropriate for that purpose.
Features & Benefits
- Eight measurement functions: Monitor pH, TDS, EC, salinity, ORP, specific gravity, chlorine-related readings and temperature.
- Chlorine-related measurement: Adds another function for customers interested in treated water conditions.
- Backlit digital display: Clear viewing of readings, including in lower-light conditions.
- Automatic Temperature Compensation (ATC): Helps account for temperature-related changes in electrical conductivity readings.
- Calibration capability: Supports calibration of applicable measurement functions using suitable reference solutions.
- Data Hold function: Retain a displayed reading for convenient recording.
- Simple function selection: Move between the supported measurement modes.
- Celsius/Fahrenheit temperature display: View temperature in your preferred unit.
- Automatic shut-off: Powers down after approximately five minutes of inactivity.
- Compact handheld design: Convenient for testing water samples at home or in different environments.
Where Is This Tester Most Useful?
- Comparing tap water with filtered water
- Monitoring changes in reverse osmosis water characteristics
- Household drinking water monitoring
- Freshwater and marine aquariums
- Hydroponic growing systems
- Saltwater monitoring and aquaculture
- Observing chlorine-related readings in treated water
- Pool and spa water monitoring alongside validated sanitiser testing
- Customers seeking a broad range of water measurement functions
How to Use Your Complete 8-in-1
- Collect a fresh water sample in a clean container.
- Remove the protective cap and switch on the tester.
- Immerse the electrode in the sample without exceeding the indicated immersion line.
- Gently stir the water and allow the reading to stabilise.
- Use the MODE button to select the measurement function you wish to view.
- View the temperature reading and switch between Celsius and Fahrenheit if required.
- Record your readings if comparing water samples or monitoring changes over time.
- After testing, rinse the electrode with distilled water and follow the supplied cleaning, calibration and storage instructions.
For reliable pH measurements, follow the manufacturer’s calibration procedures and use suitable reference solutions.
Not Sure Which One You Need?
Explore our comparison below to find the tester that best suits your requirements.
| Water Quality Tester | What It Measures | Choose This Tester If… |
|---|---|---|
| Essential 2-in-1 | TDS, Temperature | You want a simple introduction to water testing, particularly for comparing dissolved solids in tap and filtered water. |
| Everyday 4-in-1 | TDS, EC, pH, Temperature | You want to understand everyday water characteristics, including dissolved solids, conductivity and acidity or alkalinity. |
| Plus 5-in-1 | TDS, EC, pH, Salinity, Temperature | You want everyday water monitoring with the addition of salt concentration measurements for aquariums or other suitable applications. |
| Advanced 7-in-1 | TDS, EC, pH, Salinity, ORP, Specific Gravity, Temperature | You need a broader range of measurements, particularly ORP and specific gravity for specialised water monitoring. |
| Complete 8-in-1 | TDS, EC, pH, Salinity, ORP, Specific Gravity, Chlorine, Temperature | You want the widest range of measurement functions in one device, including chlorine-related readings. |
| Chlorine Check 4-in-1 | Chlorine, ORP, pH, Temperature | You’re particularly interested in monitoring selected characteristics of treated water, including chlorine-related readings. |
| TDS Monitor | TDS | You prefer a straightforward, single-purpose device for monitoring dissolved solids without additional measurement modes. |
| Advanced Classic 7-in-1 | TDS, EC, pH, Salinity, ORP, Specific Gravity, Temperature | You want an established multi-function alternative for monitoring seven water characteristics, including ORP and specific gravity. |
| Hydrogen Check 4-in-1 | Dissolved Hydrogen (H₂), ORP, pH, Temperature | You’re specifically interested in monitoring hydrogen-enriched water and its related characteristics. |
A Little Guidance Before You Choose
For everyday drinking water: The Everyday 4-in-1 is an excellent starting point, providing TDS, EC, pH and temperature measurements to help you understand and compare different water sources.
For reverse osmosis filtration: TDS and EC measurements can help you monitor changes in dissolved solids before and after filtration. Remember that remineralisation can increase the TDS of finished drinking water without necessarily indicating reduced filtration performance.
For aquariums, hydroponics and saltwater: Consider the Plus 5-in-1 or Advanced 7-in-1 if you need salinity, ORP or specific gravity measurements.
For chlorine or hydrogen monitoring: Choose a tester with the specific function you need rather than assuming more functions automatically means better results.
Technical Specifications
| Specification | Details |
|---|---|
| Model | MF-X81 |
| Measurement functions | pH, TDS, EC, Salinity, ORP, Specific Gravity, Chlorine, Temperature |
| pH range | 0–14.00 |
| pH resolution | 0.01 |
| pH accuracy | ±0.05 pH |
| TDS range | 0–9999 ppm; 10–200 ppt displayed higher range (effective range stated as 1–100 ppt) |
| TDS resolution | 1 ppm / 0.1 ppt |
| TDS accuracy | ±2% full scale |
| EC range | 0–9999 µS/cm; 10–400 mS/cm displayed higher range (effective range stated as 1–200 mS/cm) |
| EC resolution | 1 µS/cm / 0.1 mS/cm |
| EC accuracy | ±2% full scale |
| Salinity range | 0–9999 ppm / 10–200 ppt; 0.01–25% |
| Salinity accuracy | ±2% full scale |
| ORP range | ±990 mV |
| ORP resolution | 1 mV |
| ORP accuracy | ±2 mV |
| Specific Gravity range | 0–1.222 (supplier-stated) |
| Chlorine range | 0–4 ppm |
| Chlorine stated accuracy | ±0.1 ppm (method unverified) |
| Temperature range | 0–60°C / 32–140°F |
| Temperature resolution | 0.1°C / 0.1°F |
| Temperature accuracy | ±0.5°C |
| Temperature compensation | Automatic |
| Display | Backlit digital LCD |
| Data Hold | Yes |
| Automatic shut-off | Approximately 5 minutes |
| Power | 4 × 1.5V LR44 button batteries |
Specifications are based on published MF-X81 documentation. Measurement performance and particularly the chlorine function should be confirmed against the exact supplied unit.
Understanding What Your Results Mean
The Complete 8-in-1 provides measurements of selected physical and electrochemical water characteristics, but it does not offer a complete assessment of drinking water safety.
In particular:
- TDS, EC and salinity are related conductivity-based measurements, not independent contaminant tests.
- Low TDS readings do not establish that water is free from PFAS, lead, fluoride, pesticides or bacteria.
- pH indicates acidity or alkalinity, not overall water purity.
- ORP does not independently demonstrate disinfection effectiveness or antioxidant health benefits.
- The chlorine-related function has not been verified as a substitute for free or total chlorine testing.
- Specific gravity is primarily relevant to appropriate density and saltwater monitoring applications.
For specific drinking water safety concerns, suitable contaminant-specific testing or laboratory analysis may be necessary.
Pure Water. Beyond Filtered.
A better understanding of water begins with choosing the right measurements and knowing how to interpret the results.






