Description
Plus 5-in-1 Digital Water Quality Tester
A deeper understanding of your water, with five measurements in one device.
The characteristics of water can vary depending on its source, dissolved mineral content, filtration and surrounding conditions. Understanding these differences begins with measuring the parameters relevant to your needs.
The Plus 5-in-1 Digital Water Quality Tester combines TDS, EC, pH, salinity and temperature measurements in one compact handheld device, providing a practical way to monitor water conditions without requiring multiple instruments.
Whether you’re comparing tap water with filtered water, maintaining an aquarium or monitoring a hydroponic system, this versatile tester helps you observe changes and make more informed decisions about your water.
The additional salinity function makes it especially useful when salt concentrations are an important consideration.
Understanding the Five Measurements
1. TDS – Total Dissolved Solids
Total Dissolved Solids (TDS) represents the estimated concentration of dissolved substances in water, including naturally occurring mineral salts and other dissolved ions.
Readings are displayed in parts per million (ppm), or parts per thousand (ppt) at higher concentrations.
What does your reading mean?
Lower TDS: Generally indicates a lower concentration of dissolved solids.
Higher TDS: Generally indicates a greater concentration of dissolved solids.
TDS monitoring is particularly useful when comparing water sources or observing changes before and after reverse osmosis filtration.
It’s important to remember that a higher TDS reading does not necessarily indicate harmful water, and a lower reading does not automatically mean the water is safe to drink.
2. EC – Electrical Conductivity
Electrical Conductivity measures how readily water conducts electricity, which depends largely on the concentration of dissolved ions.
EC is expressed in microsiemens per centimetre (µS/cm) or millisiemens per centimetre (mS/cm).
How does EC relate to TDS?
Most handheld water testers measure electrical conductivity and calculate an estimated TDS value using a conversion factor.
The two measurements are therefore closely related, rather than independent measures of water purity.
EC is especially useful in hydroponics, aquariums and other applications where changes in dissolved ions are important.
3. pH – Acidity & Alkalinity
pH indicates how acidic or alkaline a water sample is on a scale from 0 to 14.
Below pH 7: Acidic
pH 7: Neutral
Above pH 7: Alkaline
Monitoring pH can help you understand changes in water chemistry, including after certain filtration or remineralisation processes.
pH is also particularly relevant in aquariums and hydroponic systems, where maintaining suitable water conditions is important.
4. Salinity – Salt Concentration
Salinity estimates the concentration of dissolved salts in water.
This measurement is particularly useful in marine aquariums, aquaculture and other water systems where salt concentration matters.
How does salinity differ from TDS and EC?
TDS estimates overall dissolved solids, while EC measures electrical conductivity. Salinity provides a salt concentration estimate derived from conductivity and a conversion method.
These measurements are related but are expressed differently for particular applications.
For saltwater systems, understanding salinity can help you observe changes in dissolved salt concentration over time.
5. Water Temperature
Temperature influences water conditions and electrical conductivity measurements.
The Plus 5-in-1 provides temperature readings in degrees Celsius or Fahrenheit, allowing you to monitor this parameter alongside the other measurements.
Temperature is particularly important when maintaining aquariums, hydroponic systems and other water environments.
Monitoring Water Before & After Filtration
Reverse osmosis filtration is designed to substantially reduce many dissolved substances in water.
Comparing TDS and EC readings from incoming tap water with water produced by a reverse osmosis system can help you observe changes in dissolved solids and conductivity.
The pH measurement can also provide useful information about changes in acidity or alkalinity.
What about remineralised RO water?
Some reverse osmosis systems include a remineralisation stage that adds minerals back into the water after filtration.
This may increase the final water’s TDS and EC readings and can influence pH, depending on the minerals added and the water chemistry.
An increase in dissolved solids after remineralisation does not necessarily indicate a problem with the reverse osmosis membrane.
When evaluating dissolved solids reduction by the membrane, test before the remineralisation stage where an appropriate sampling point is available.
Features & Benefits
- Five measurement functions: Monitor TDS, EC, pH, salinity and temperature using one handheld tester.
- Salinity measurement: Provides additional information about estimated salt concentrations.
- Backlit digital display: Clear readings, including in lower-light conditions.
- Automatic Temperature Compensation (ATC): Helps account for temperature-related changes in conductivity measurements.
- pH calibration capability: Supports calibration using suitable pH reference solutions.
- Data Hold function: Retain a reading on the display for convenient recording.
- Simple measurement selection: Switch between supported measurement functions.
- Portable handheld design: Convenient for testing different water sources and environments.
- Automatic shut-off: Powers down after approximately five minutes of inactivity.
Where Is This Tester Most Useful?
- Comparing household tap water with filtered water
- Monitoring reverse osmosis filtration
- Freshwater and marine aquarium monitoring
- Hydroponic growing systems
- Saltwater and aquaculture applications
- Observing changes in salinity
- Comparing water samples from different sources
- General water monitoring where multiple measurements are useful
How to Use Your Plus 5-in-1
- Collect a fresh water sample in a clean container.
- Remove the protective cap and switch on the tester.
- Immerse the electrode in your water sample without exceeding the indicated immersion line.
- Gently stir and allow the displayed reading to stabilise.
- Select the desired measurement mode to view TDS, EC, pH or salinity.
- View the temperature reading using the appropriate function control.
- Record your results if comparing measurements over time.
- Rinse the electrode with distilled water after testing and follow the supplied storage instructions.
For accurate pH readings, calibrate the tester according to the manufacturer’s instructions using appropriate calibration solutions.
Not Sure Which One You Need?
Explore our comparison below to find the tester that best suits your requirements.
| Water Quality Tester | What It Measures | Choose This Tester If… |
|---|---|---|
| Essential 2-in-1 | TDS, Temperature | You want a simple introduction to water testing, particularly for comparing dissolved solids in tap and filtered water. |
| Everyday 4-in-1 | TDS, EC, pH, Temperature | You want to understand everyday water characteristics, including dissolved solids, conductivity and acidity or alkalinity. |
| Plus 5-in-1 | TDS, EC, pH, Salinity, Temperature | You want everyday water monitoring with the addition of salt concentration measurements for aquariums or other suitable applications. |
| Advanced 7-in-1 | TDS, EC, pH, Salinity, ORP, Specific Gravity, Temperature | You need a broader range of measurements, particularly ORP and specific gravity for specialised water monitoring. |
| Complete 8-in-1 | TDS, EC, pH, Salinity, ORP, Specific Gravity, Chlorine, Temperature | You want the widest range of measurement functions in one device, including chlorine-related readings. |
| Chlorine Check 4-in-1 | Chlorine, ORP, pH, Temperature | You’re particularly interested in monitoring selected characteristics of treated water, including chlorine-related readings. |
| TDS Monitor | TDS | You prefer a straightforward, single-purpose device for monitoring dissolved solids without additional measurement modes. |
| Advanced Classic 7-in-1 | TDS, EC, pH, Salinity, ORP, Specific Gravity, Temperature | You want an established multi-function alternative for monitoring seven water characteristics, including ORP and specific gravity. |
| Hydrogen Check 4-in-1 | Dissolved Hydrogen (H₂), ORP, pH, Temperature | You’re specifically interested in monitoring hydrogen-enriched water and its related characteristics. |
A Little Guidance Before You Choose
For everyday drinking water: The Everyday 4-in-1 is an excellent starting point, providing TDS, EC, pH and temperature measurements to help you understand and compare different water sources.
For reverse osmosis filtration: TDS and EC measurements can help you monitor changes in dissolved solids before and after filtration. Remember that remineralisation can increase the TDS of finished drinking water without necessarily indicating reduced filtration performance.
For aquariums, hydroponics and saltwater: Consider the Plus 5-in-1 or Advanced 7-in-1 if you need salinity, ORP or specific gravity measurements.
For chlorine or hydrogen monitoring: Choose a tester with the specific function you need rather than assuming more functions automatically means better results.
Technical Specifications
| Specification | Details |
|---|---|
| Model | MF-X51 |
| Measurement functions | TDS, EC, pH, Salinity, Temperature |
| pH range | 0–14.00 |
| pH resolution | 0.01 |
| pH accuracy | ±0.05 pH |
| TDS range | 0–9999 ppm; 10–200 ppt higher range |
| TDS resolution | 1 ppm / 0.1 ppt |
| TDS accuracy | ±2% full scale |
| EC range | 0–9999 µS/cm; 10–200 mS/cm higher range |
| EC resolution | 1 µS/cm / 0.1 mS/cm |
| EC accuracy | ±2% full scale |
| Salinity range | 0.01–25%; additional ppm/ppt ranges |
| Salinity accuracy | ±2% full scale |
| Temperature range | 0–60°C / 32–140°F |
| Temperature resolution | 0.1°C / 0.1°F |
| Temperature accuracy | ±0.5°C |
| Temperature compensation | Automatic |
| Display | Backlit digital display |
| pH calibration | Three-point (pH 4.00, 6.86, 9.18) |
| Data Hold | Yes |
| Auto shut-off | Approximately 5 minutes |
| Power | 4 × 1.5V LR44 batteries |
Specifications are based on published MF-X51 and MF-X series documentation. Some sources list a different extended EC range, so the exact supplied unit should take precedence.
Understanding What Your Results Mean
The Plus 5-in-1 measures selected characteristics of water. These measurements can be useful for observing changes and monitoring water systems, but they do not provide a complete assessment of drinking water safety.
In particular:
- TDS, EC and salinity are related conductivity-based measurements.
- These readings do not identify individual dissolved substances.
- A low TDS reading does not establish that water is free from PFAS, heavy metals, bacteria or other contaminants.
- pH indicates acidity or alkalinity, not overall water purity.
- Salinity measurements do not replace laboratory analysis where precise salt concentrations are essential.
For specific water safety concerns, suitable contaminant-specific testing or laboratory analysis may be necessary.
Pure Water. Beyond Filtered.
Understanding your water means choosing the measurements that matter — and recognising what those results can tell you.